Anthropometric Measurements · Experience 05

Bi-iliac Breadth VR Nursing Simulation

The learner locates the iliac crests, positions the caliper at a slight downward angle and applies enough pressure to measure pelvic breadth accurately.

Bi-iliac Breadth VR Nursing Simulation
Under constructionAnthropometric MeasurementsExperience 5 of 17
This scenario is under construction. The scenarios below describe the training content that is being finalised. Contact Enmatech Oman for the expected release date or a preview.

Learning objectives

By the end of this experience the learner can:

  • Locate the anatomical landmarks for bi-iliac breadth: between the most lateral points of the iliac crests, blades pressed firmly to reduce soft-tissue error.
  • Use the large sliding caliper correctly and read it to the required precision.
  • Position the patient correctly and repeat the measurement to confirm consistency.
  • Record the value with the side measured and compare it with reference ranges.
Bi-iliac Breadth VR Nursing Simulation

Procedure steps

  1. Explain the measurement to the virtual patient and position them as required.
  2. Palpate and mark the landmarks (between the most lateral points of the iliac crests, blades pressed firmly to reduce soft-tissue error).
  3. Apply the large sliding caliper as demonstrated and take the reading.
  4. Repeat the measurement; if the two readings differ beyond the tolerance, take a third.
  5. Record the mean value and the instrument used.

Assessment

Landmark accuracy, instrument placement and the difference between the learner's reading and the reference value are checked automatically, with a tolerance set by the instructor.

Equipment and setting

Instrument: large sliding caliper. Landmarks: between the most lateral points of the iliac crests, blades pressed firmly to reduce soft-tissue error.

Frequently asked

Bi-iliac Breadth FAQ

What educators ask about this scenario.

What will I practise in the Bi-iliac Breadth scenario?

The learner locates the iliac crests, positions the caliper at a slight downward angle and applies enough pressure to measure pelvic breadth accurately.

How is performance assessed?

Landmark accuracy, instrument placement and the difference between the learner's reading and the reference value are checked automatically, with a tolerance set by the instructor.

Discuss your medical VR training requirements with Enmatech Oman

  • Create virtual reality and augmented reality experiences at the best prices
  • Equipping engineering laboratories with the best equipment
  • Virtual tours with 360° technology that you can view through just one link