Anthropometric Measurements · Experience 12

Elbow Breadth VR Nursing Simulation

Used to estimate frame size, elbow breadth is measured by placing the caliper blades on the epicondyles at a slight angle and applying firm pressure.

Elbow Breadth VR Nursing Simulation
Under constructionAnthropometric MeasurementsExperience 12 of 17
This scenario is under construction. The scenarios below describe the training content that is being finalised. Contact Enmatech Oman for the expected release date or a preview.

Learning objectives

By the end of this experience the learner can:

  • Locate the anatomical landmarks for elbow breadth: between the medial and lateral epicondyles of the humerus with the elbow flexed at 90°.
  • Use the small sliding caliper correctly and read it to the required precision.
  • Position the patient correctly and repeat the measurement to confirm consistency.
  • Record the value with the side measured and compare it with reference ranges.
Elbow Breadth VR Nursing Simulation

Procedure steps

  1. Explain the measurement to the virtual patient and position them as required.
  2. Palpate and mark the landmarks (between the medial and lateral epicondyles of the humerus with the elbow flexed at 90°).
  3. Apply the small sliding caliper as demonstrated and take the reading.
  4. Repeat the measurement; if the two readings differ beyond the tolerance, take a third.
  5. Record the mean value and the instrument used.

Assessment

Landmark accuracy, instrument placement and the difference between the learner's reading and the reference value are checked automatically, with a tolerance set by the instructor.

Equipment and setting

Instrument: small sliding caliper. Landmarks: between the medial and lateral epicondyles of the humerus with the elbow flexed at 90°.

Frequently asked

Elbow Breadth FAQ

What educators ask about this scenario.

What will I practise in the Elbow Breadth scenario?

Used to estimate frame size, elbow breadth is measured by placing the caliper blades on the epicondyles at a slight angle and applying firm pressure.

How is performance assessed?

Landmark accuracy, instrument placement and the difference between the learner's reading and the reference value are checked automatically, with a tolerance set by the instructor.

Discuss your medical VR training requirements with Enmatech Oman

  • Create virtual reality and augmented reality experiences at the best prices
  • Equipping engineering laboratories with the best equipment
  • Virtual tours with 360° technology that you can view through just one link