Anthropometric Measurements · Experience 14

Triceps Skinfold VR Nursing Simulation

The learner grasps a vertical fold of skin and subcutaneous fat 1 cm above the mark, applies the caliper at the mark and reads after two seconds, repeating until two readings agree.

Triceps Skinfold VR Nursing Simulation
Under constructionAnthropometric MeasurementsExperience 14 of 17
This scenario is under construction. The scenarios below describe the training content that is being finalised. Contact Enmatech Oman for the expected release date or a preview.

Learning objectives

By the end of this experience the learner can:

  • Locate the anatomical landmarks for triceps skinfold: vertical fold on the posterior midline of the upper arm at the marked midpoint, arm relaxed.
  • Use the skinfold caliper correctly and read it to the required precision.
  • Position the patient correctly and repeat the measurement to confirm consistency.
  • Record the value with the side measured and compare it with reference ranges.
Triceps Skinfold VR Nursing Simulation

Procedure steps

  1. Explain the measurement to the virtual patient and position them as required.
  2. Palpate and mark the landmarks (vertical fold on the posterior midline of the upper arm at the marked midpoint, arm relaxed).
  3. Apply the skinfold caliper as demonstrated and take the reading.
  4. Repeat the measurement; if the two readings differ beyond the tolerance, take a third.
  5. Record the mean value and the instrument used.

Assessment

Landmark accuracy, instrument placement and the difference between the learner's reading and the reference value are checked automatically, with a tolerance set by the instructor.

Equipment and setting

Instrument: skinfold caliper. Landmarks: vertical fold on the posterior midline of the upper arm at the marked midpoint, arm relaxed.

Frequently asked

Triceps Skinfold FAQ

What educators ask about this scenario.

What will I practise in the Triceps Skinfold scenario?

The learner grasps a vertical fold of skin and subcutaneous fat 1 cm above the mark, applies the caliper at the mark and reads after two seconds, repeating until two readings agree.

How is performance assessed?

Landmark accuracy, instrument placement and the difference between the learner's reading and the reference value are checked automatically, with a tolerance set by the instructor.

Discuss your medical VR training requirements with Enmatech Oman

  • Create virtual reality and augmented reality experiences at the best prices
  • Equipping engineering laboratories with the best equipment
  • Virtual tours with 360° technology that you can view through just one link